top of page

How Does a Commercial Solar Microgrid Prevent Power Outages?

Writer: Ben Westcott
Ben Westcott
Nov 2
7 min read

Updated: Nov 11

Key takeaways

  • A standard commercial solar system switches off during a power cut, even on a sunny day. That's a legal safety requirement, not a fault.

  • A solar microgrid adds battery storage, island-capable inverters, isolation switchgear and a controller, so your site can disconnect from the grid and keep running on its own.

  • Microgrids don't stop the grid failing. They stop a grid failure from shutting down your critical operations, usually for hours rather than indefinitely.

  • Backup has to be designed in from the start and sized around your critical loads. It pays best when the same battery also cuts your energy bills every day.

 

Does commercial solar work during a power cut?

Not on its own. A standard grid-connected solar system shuts down automatically within a fraction of a second of a grid failure, however sunny it is. This anti-islanding protection is required under the G98 and G99 connection standards, to stop solar power flowing back into lines that network engineers may be repairing.


This surprises many businesses. UK grid-connected systems must comply with G98/G99 and BS 7671, which require them to shut down automatically when the grid fails. If a system kept exporting onto a circuit engineers believed was dead, it could cause serious or fatal injury. The inverter constantly monitors grid voltage and frequency and disconnects the moment either moves outside the permitted range.


Adding a battery doesn't automatically change that. In a standard setup, the inverter shuts down and the battery sits idle until the grid returns. Backup only works when the system is specifically designed and wired to run as a safe, isolated island.

infographic on what happens when the grid goes down

What is a commercial solar microgrid?

A commercial solar microgrid is an on-site energy system that can run connected to the grid or disconnect and operate independently. It combines solar panels with battery storage, inverters that can form their own local grid, switchgear that safely isolates the site, and a controller that manages the switchover and balances supply and demand.


The key difference is intentional islanding. An unintentional island forms unexpectedly and is dangerous. An intentional island is designed to disconnect from the grid and operate independently, with proper isolation and protection. A microgrid is built to do the second safely.


A typical commercial microgrid includes:

  • Solar PV: generates electricity during daylight and recharges the battery during an outage.

  • Battery storage: holds energy to power the site at night, in poor weather, or when demand exceeds solar output.

  • Grid-forming or backup-capable inverters: create a stable local supply when the grid isn't there to follow.

  • Isolation switchgear: physically separates the site from the grid before the island starts, so no power flows back onto the network.

  • A microgrid controller or energy management system: decides when to island, which loads to supply, and how to reconnect safely.

  • Optional backup generation: some sites require a generator for very long outages or winter resilience.

infographic showing what's inside a commercial solar microgrid

 

How does a solar microgrid keep your site running in an outage?

When the grid fails, the controller detects it, opens the isolation switch to disconnect your site, and the battery inverters take over supplying your critical circuits, often within milliseconds. The solar keeps generating and recharging the battery during daylight. When the grid returns and is stable, the system resynchronises and reconnects automatically.


Step by step, a well-designed system works like this:

  1. The grid fails. The controller and inverters detect the loss of supply.

  2. The site isolates. Switchgear disconnects your site from the network, meeting the same safety principle as anti-islanding.

  3. The island forms. The battery inverters create a local supply for your backed-up circuits. Some systems switch over fast enough that sensitive equipment doesn't notice.

  4. Solar keeps working. Panels continue generating and recharge the battery during daylight, extending backup time.

  5. Loads are managed. The controller can shed lower-priority circuits to make stored energy last longer.

  6. The grid returns. Once the supply is stable, the site resynchronises and reconnects without manual intervention.

infographic showing how a microgrid keeps your site running

Some sites can be large and have complex electrical infrastructure which wouldn't allow the solar microgrid to back up the entire site. In these cases, a dedicated essential design can be integrated, providing resilience to fire safety and IT equipment.


As part of the DNO/IDNO Application process, an assessment is made to whether the introduction of AC or DC Coupled inverters is best for the installation and if the site requires any export back to the grid.


Why does power resilience matter for UK businesses?

The UK grid is generally reliable, but outages still happen, and a single failure can take out a large area. For businesses with refrigeration, continuous production, critical IT or vulnerable people on site, even a few hours without power can mean lost stock, missed orders, safety risks and damaged equipment.


The North Hyde substation fire in March 2025 is the clearest recent example. A fire at one West London substation knocked out power to nearly 67,000 customers as well as Heathrow Airport. According to the National Energy System Operator's review, three data centres lost power but kept operating on backup generators, and power was restored to directly supplied customers by midday the following day.


Duration is the lesson. The independent review of Heathrow's response found that nearly all emergency power sources connected to the North Hyde supply would have been depleted before main power was restored. Backup that runs out too soon doesn't protect you.

infographic showing why energy resilience matters

Where this matters most:

  • Cold storage and food and beverage: a refrigeration failure can mean spoiled stock and food safety breaches within hours.

  • Manufacturing: an unplanned stop can scrap work in progress and take hours to restart safely.

  • Healthcare, hospices and care settings: keeping lighting, heating, medical equipment and communications running protects vulnerable people.

  • Schools and multi-academy trusts: power loss can close a school for the day. Keeping safeguarding systems, IT and heating on may allow it to stay open.

  • Logistics and warehousing: loss of automation, conveyors, IT and dock doors can halt dispatch.

 

How much does a commercial solar microgrid cost?

The main extra cost over standard solar is battery storage, which industry guides put at roughly £200 to £700 per kWh installed for commercial systems, depending on size and site. Backup capability adds further cost for island-capable inverters, switchgear and controls. The total depends mostly on how much load you need to keep running, and for how long.


Published 2026 figures vary widely. One industry guide puts mid-size commercial storage at £200 to £450 per kWh installed, while another quotes £400–£700 per kWh for 50–500 kWh systems, falling to £350–£550 at 1 MWh and above. The same source notes that costs rise when you add advanced controls or islanding and backup capability.


The simplest way to size backup is critical load multiplied by backup duration. For example, keeping 50kW of critical load running for four hours needs roughly 200kWh of usable storage. At the published ranges above, the battery alone would be in the region of £40,000 to £140,000 before islanding equipment, and solar can extend that runtime during daylight. These are illustrative figures only.


The economics change when the same battery works every day. Most businesses don't buy a battery purely for backup. It pays its way by storing surplus solar, cutting peak demand charges and shifting energy into expensive periods. Resilience then becomes a valuable extra, rather than the whole business case.

infographic showing an example of how much a backup costs

Solar microgrid vs diesel generator vs UPS: which do you need?

Each does a different job. A UPS bridges seconds to minutes for sensitive equipment. A diesel generator can run for days if it has fuel, but earns nothing when the grid is up. A solar microgrid covers hours of critical load, recharges from the sun, and cuts energy costs every day. Many resilient sites use a combination.

infographic comparing the different backup energy systems

Our verdict for each type of site:

  • Sites that already have a generator: add solar and storage to cut costs, and let the battery bridge the gap while the generator starts. The generator becomes a last resort rather than your first line of defence.

  • Cold storage, food manufacturing and care settings: size a microgrid around the loads that protect stock, safety and people, and keep a generator or hire contract for very long outages.

  • Offices, warehouses and schools with low outage risk: a microgrid is rarely worth it for resilience alone. Buy storage for the savings and add backup to a critical-load board if the extra cost is modest.

  • Data centres and critical national infrastructure: you'll need multiple layers, including UPS and generation. Solar and storage can reduce costs and fuel use, but won't replace dedicated resilience engineering.

 

What are the limitations of a solar microgrid?

A solar microgrid won't usually run a whole site indefinitely. Battery capacity limits how long you can supply heavy loads, winter solar output is low, and backup must be designed in from the start. It also adds cost and complexity, and your DNO needs to be satisfied that the site isolates safely from the grid.

  • Limited duration. Batteries are sized for hours, not days. In winter, solar may barely recharge them.

  • Critical loads only. Backing up an entire site is usually uneconomic. Most designs protect a chosen set of circuits.

  • Must be designed in. Backup must be specified and designed in at the time of installation. Retrofitting is possible but may need new inverters and switchgear.

  • Space and safety. Commercial batteries need suitable plant space, ventilation and fire safety measures, which not every site can provide easily.

  • Grid connection requirements. Islanding equipment must be approved as part of your G99 connection, which can add design and approval time.

  • Testing. Like any backup system, a microgrid needs regular testing. Backup that has never been tested is a hope, not a plan.

 

infographic giving an honest opinion on solar micro grids

Frequently asked questions

Will my solar panels keep working in a power cut?

Not unless your system is designed for backup. Standard grid-connected systems shut down automatically for safety. You need battery storage with island-capable inverters and isolation equipment.

Often, yes. But it may need new or upgraded inverters, isolation switchgear and a critical-load board, plus an updated G99 application. A site survey will confirm what's needed.

That depends on the battery size, your critical load and the weather. A typical commercial design covers several hours of critical load, extended during daylight as the solar recharges the battery.

No. A battery is one component. A microgrid also needs inverters that can form a local grid, switchgear to isolate your site, and a controller to manage the switchover.

For short outages, often yes. For long outages or very large loads, most sites keep a generator as a last resort. A combination usually gives the best resilience at the lowest running cost.

BESS can be funded under a PPA. The structure of the deal and access to BESS features and benefits will need to be established and understood at the earliest possible point to ensure a successful outcome for all parties.



As with all onsite energy projects, the key to success is honest and open dialog between you and your developer to ensure the physical equipment and legal structures commercially are commercially aligned with your goals.


Talk to our team to see how we can help with your energy resilience.

bottom of page